AWG Cables

AWG Rubber/HR PVC Insulated Flat cables

Information

Technical Data
  • Operating Temp: PVC: -40°c to max.+90°C, Rubber: -40°c to max.+90°C
  • Nominal voltage: 600 V
  • Test voltage: 2000 V
  • Flame propagation: Flame retardant test as per UL 83, VW-1
Cable Structure

generally conforms to, CENELEC HD 21, UL-83, IEC 60227, BS 6500, DIN VDE 0281, IS 694
• Insulation as per TW,THW,THHW,THW-2

Copper:
EC flexible copper as per ASTM B-3, IEC 60228, DIN VDE 0295

Insulation:
Special PVC:as per UL 83
Special Rubber:as per UL 83

Outer Sheath:
Special PVC:as per UL 83
Special Rubber:as per UL 83

Cable features (PVC Pump Cables)
  • Exceptional long term performance
  • Suitable for 90°C dry & 75°C wet
  • Excellent resistant to oils, chemicals, ozone & solvents
  • Excellent Impact, Weather Resistant
  • Excellent Electrical Properties
  • Tested by INTERTEK, SGS, EIL, RITES, NPC
Cable features (Rubber Pump Cables)
  • 90°C oil, zone & water resistant rubber insulation
  • Exceptional long term performance
  • Performs & Looks like Vulcanize Rubber
  • RoHS compliance
  • Excellent resistant to oils, chemicals, ozone & solvents
  • Excellent Impact, Weather Resistant
  • Excellent Electrical Properties
  • Tested by INTERTEK, SGS, EIL, RITES, NPC
Application

PVC Flat – 3 & 4 Core
AWG pump cables designed for use as submersible pump, deep well and motor lead cable up to the depth of 500 m and water temperature up to +90°C.

Cable Design

A submersible Pump cable is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Jainam is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability.

Cores colour: Core Identification
Color coding As per IEC 60227
3 core without ground Red, Yellow and Black
4 core with ground Red, Yellow, Black and Green

Technical DataTable

Flat Jacketed Submersible Pump Cables Without GroundFlat Jacketed Submersible Pump Cables With Ground
Flat Jacketed Submersible Pump Cables Without Ground
Cross sectional area
of conductor
No of conductor Configuration Nominal thickness
of sheath
Mean overall dimeter
width x height
AWG Nos. Nos. x Dia mm mm
14 3 41 x 0.254 1.15 14.60 x 6.40
12 3 65 x 0.254 1.15 16.80 x 7.40
10 3 105 x 0.254 1.15 18.70 x 7.90
8 3 168 x 0.254 1.4 23.70 x 9.90
6 3 226 x 0.254 1.4 28.00 x 11.40
4 3 420 x 0.254 2 35.50 x 14.70
2 3 665 x 0.254 2 39.50 x 16.20
1 3 817 x 0.254 2.2 45.50 x 18.30
1/0 3 1045 x 0.254 2.2 45.50 x 18.30
2/0 3 1330 x 0.254 2.2 51.00 x 20.00
3/0 3 1672 x 0.254 2.4 60.00 x 23.50
4/0 3 2116 x 0.254 2.65 65.00 x 25.00
Flat Jacketed Submersible Pump Cables With Ground
Cross sectional area
of conductor
No of conductor Configuration Nominal thickness
of sheath
Mean overall dimeter
width x height
AWG Nos. Nos. x Dia mm mm
14 4 41 x 0.254 1.15 18.00 x 6.50
12 4 65 x 0.254 1.15 21.00 x 7.60
10 4 105 x 0.254 1.15 24.30 x 7.90
8 4 168 x 0.254 1.4 29.70 x 9.90
6 4 226 x 0.254 2 36.00 x 11.80
4 4 420 x 0.254 2 45.10 x 14.70
2 4 665 x 0.254 2.2 50.10 x 16.20
1 4 817 x 0.254 2.2 58.10 x 19.00
1/0 4 1045 x 0.254 2.2 58.10 x 19.00
2/0 4 1330 x 0.254 2.2 66.50 x 21.50

Other Products